Globe Valves vs Ball Valves

There are many different types of valves for different applications, so how do you know which is the best to use for your application?  We’ll start by looking at globe valves and ball valves.  The main difference between these two types is the way they close.  A globe valve uses a plug (stem) that closes against the flow, and a ball valve has a gate (ball) that closes across the flow.  Globe valves are good for regulating flow, whereas ball valves are better for on/off control without pressure drop. 

For many decades globe valves were considered the industry standard in control valves.  They are designed with a stem that moves up and down inside the valve to control flow.  They are commonly used on hot and chill water coils, and larger models are often used to control flow to chillers.  One of the main limitations of globe valves is that their close-off rating can be lower than other valves, especially in the larger sizes.

Ball valves are designed with a ball inside the valve.  The ball has a hole through the middle so that when the hole is in line with both ends of the valve, flow will occur.  When the valve is closed by turning the ball 90 degrees, the hole is perpendicular to the ends of the valve, and therefore flow is blocked.  Ball valves are very durable and usually have excellent shutoff even after years of use.  They are generally preferred over globe valves in shutoff applications.  The main limitation for ball valves is proportional control because of the large amount of flow that the ball allows. 

Check back soon for more valve comparisons.  Up next, 2-way vs. 3-way valves.  Until then, I hope everyone has a Happy New Year!

Facebook
Twitter
LinkedIn
Pinterest

8 Responses

  1. Back seated union bonnet globes should be used for isolation and shut off
    because you can quickly repair them.
    Most ball valves use o rings, o rings are a poor choice for a rotating seal.
    3 piece balls offer easy repair but we are too cheap to buy them and you cannot
    replace the packing under pressure like the back seated valve.
    Show me a 30 year old actuated ball valve that still works.
    I see globes older than that every day
    Pat

  2. Hello Sales,

    Our Company acting as potential buyer of your products and
    services,request a quote for the following product (s)-

    (1)Item 1″ inch Threaded 150# Galvanized Malleable Iron 90 Degree Elbow

    (2)Item 1” in. Brass Threaded Ball Valve Full Port

    Please revert back to me with all relevant information, options, and
    suitable alternatives.

    Note: In addition to the above,Our Company standard Payment terms:Net 30
    days from the date of supply with the supplier’s Invoice. Kindly Send
    your company credit application form alongside with the quote price for
    the product above.

    Thanks,

    Josh Roger
    Veritas Technologies LLC
    Procurement Dept.
    500 East Middlefield Road
    Mountain View CA 94043
    Phone: (657) 306-4732

Leave a Reply

Your email address will not be published. Required fields are marked *

Stay In The Know. Join The Control Trends Newsletter.